内容 研究発表
9巻2号2004年
Page 75
題名 ORP control for nitrogen removal from sewage with low C/N ratio in a hybrid biofilm pilot plant
Title ORP control for nitrogen removal from sewage with low C/N ratio in a hybrid biofilm pilot plant
著者 Y. O. Kim*,H. U. Nam*,I. G. Byun**,T. J. Park** and T. H. Lee*
Authors Y. O. Kim*,H. U. Nam*,I. G. Byun**,T. J. Park** and T. H. Lee*
著者表記
著者表記(英)
著者勤務先名
Office name
著者所属名
キーワード
Key Words Denitrification; external carbon source; low C/N ratio; nitrogen removal; ORP control
概要
Abstract An oxidation reduction potential (ORP) control system, which adjusted amount of external carbon source for denitrification based on ORP values, was applied to a hybrid biofilm pilot plant for cost-effective removal of nitrogen from sewage with low C/N ratio. The pilot plant consisted of serially anoxic-, aerobic-, anoxic-, aerobic-reactor and both aerobic reactors were separated two parts with a baffle. Influent BOD and total nitrogen (T-N) concentrations were varied in the rage of 25.0-140.5 mg/L and 15.5-46.5 mg/L, respectively. Because the C/N ratio (1.6-3.0) of the influent was too low to complete denitrification, an external carbon source of methanol was added to the second anoxic reactor to meet the regulation limit of effluent T-N, 10.0 mg/L. The effluent T-N concentration was directly affected by methanol addition in the tested concentration range, 50 to 100 mg/L as final concentration in the second anoxic reactor. An empirical equation decided from the ORP values according to added methanol amount was ORP = 0.0055[methanol]2 - 2.2733[methanol] + 37.402. The concentration of methanol addition was decided from an empirical equation according to the ORP value measured in the second anoxic reactor. As a result of applying the ORP automatic control system, 20% of the amount of methanol addition was reduced comparing with the fixed amount addition of methanol as final concentration as 75 mg/L without ORP control system. These results suggested that ORP auto-control system would be applied to efficient and cost effective removal of nitrogen from sewage with low C/N ratio.
 
全文閲覧をご希望の方
◆全文PDFファイルのお申込みの前に
年会費5,000円にて本誌の購読と論文全誌のWeb閲覧がご利用頂けます。
ご入会は、こちらからお願いします。
ご入会のお申し込みフォームはこちらから
この論文は、無料公開されています。
ダウンロードは、右のリンクからどうぞ。
(注)Internet Explorerをお使いの場合、正しいファイル名でダウンロードされない場合があります。
全文ダウンロード
Line
 


ページの先頭に戻る

line
HOME | 利用規約 | プライバシーポリシー | サイトマップ | お問合わせ | 管理者ログイン
line
[ 環境システム計測制御学会事務局 ]
〒573-1116 大阪府枚方市船橋本町1-775 株式会社Atalacia内
TEL:072-807-3890 FAX:072-807-3898
Copyright(C) 2008-2017 The Society of Environmental Instrumentation Control and Automation. All Rights Reserved.